Hipot & Insulation Resistance Testers

TH9010 Series

Parallel Multi-Channel AC/DC Withstand Voltage & Insulation Resistance Tester

A parallel multi-channel hipot tester. A single instrument tests up to eight channels at the same time and judges each channel's PASS/FAIL result independently, like running up to eight single-channel testers in parallel. Each channel can be extended with a TH90101 four-channel scanner, so one TH9010 can grow to as many as 128 test points.

TH9010 CE

Technical question about this series? Ask our team.

Key features

  • 8-channel parallel high-voltage output, up to 8× the throughput of a single-channel tester
  • Each of the 8 test units is fully independent, no channel-to-channel interference
  • Scalable to 128 test points with up to four TH90101 four-channel scanners per unit
  • Scanner channels support contact-check (connection-integrity) verification
  • Open/short-circuit detection (OSC) flags bad contacts before high voltage is applied
  • Rapid discharge and arc (ARC) detection
  • Ground-fault / electric-shock protection shuts down output automatically
  • Programmable rise/fall time and test time, 0.1–999.9 s
  • Independent PASS/FAIL per channel plus one overall file result
  • Stores 100 test files (up to 20 steps each); import/export via front-panel USB

Model

TH9010

8 independent parallel channels

AC withstand
5 kV / 10 mA
DC withstand
6 kV / 5 mA
Insulation test voltage
0.1–1 kV
Scan expander
TH90101 (8×4)
Max. test points
128
Request a quote for TH9010

All eight test units share the same per-channel electrical performance. Standard safety functions (OSC, ARC, contact check, ground-fault protection) apply to every channel.

Applications

Production and automated test

Automated test systems, transformers and motors, electrical equipment, where parallel multi-channel testing raises line throughput without adding floor space.

Appliances and components

Household appliances, electronic components and lighting products requiring routine withstand-voltage and insulation-resistance safety testing.

Automotive and medical

New-energy vehicle components and medical equipment, where independent per-channel PASS/FAIL judgement supports batch and multi-DUT test cells.

Industries and application examples

Technical specifications

ParameterTH9010
Number of test units 8 independent channels
Output voltage, AC 0.10 – 5.00 kV ±2%
Output voltage, DC 0.10 – 6.00 kV ±2%
Current test range, AC 0 – 10.00 mA ±(2% reading + 5 digits)
Current test range, DC 0 – 5.00 mA ±(2% reading + 5 digits)
Rapid discharge Automatic discharge after test ends (DCW)
IR output voltage 0.10 – 1.00 kV ±2%
IR resistance range 0.1 MΩ – 10.0 GΩ
IR accuracy at ≥ 500 V 1–100 MΩ ±(5% F.S. + 5 digits); 100 MΩ–1 GΩ ±(10% F.S. + 5 digits)
IR accuracy at < 500 V 0.1–100 MΩ ±(10% F.S. + 5 digits)
IR accuracy above 1 GΩ Reference only, no accuracy specified (any test voltage)
Arc detection 1 – 20 mA
Voltage rise / fall time 0.1 – 999.9 s
Test time (AC/DC) 0.2 – 999.9 s
Waiting time (IR) 0.2 – 999.9 s
Time accuracy ±(1% + 0.1 s)
Memory 100 test files, up to 20 test steps per file
Scan expander TH90101 (8×4 ports)
Max. test channels (with scanners) 128
Dimensions (W × H × D) 430 × 177 × 630 mm
Net weight 38 kg

Source: TH9010 Datasheet, Rev. 2026-11. Specifications subject to change without notice.

Interfaces

  • RS232standard
  • USB Hoststandard
  • USB Devicestandard
  • Handlerstandard
  • SCPIstandard
  • GPIBoptional

Accessories

Standard accessories

ItemDescription
—EU power cable (Schuko, CEE 7/7)
TH26034RS232 connection cable
TH90016HV test cable (without clips)
TH90015HV test cable (with clips)
—Anti-interference ferrite ring × 8

Optional test fixtures

ItemDescription
TH901018-unit

Up to four scan expanders can be cascaded per unit. Ask Techmize or your authorized distributor for test-fixture options.

Photos of fixtures and accessories: click an item code above, or browse all accessories.

Downloads

Interested in the TH9010 Series?

Send us the model, quantity and your application. Our team in Ismaning will answer by email.

Request a quote