TH2840 Series
Precision LCR Digital Bridge, up to 2 MHz
A dual-CPU architecture separates measurement processing from display refresh, giving the TH2840 series up to 1800 readings/s while a 10.1" capacitive touchscreen shows four measurement parameters, sorting results and status at once. Three models span 20 Hz to 2 MHz, covering component evaluation, dielectric/magnetic material characterization and high-throughput production-line sorting.
Technical question about this series? Ask our team.
Key features
- Dual-CPU architecture: up to 1800 readings/s (0.56 ms) test speed
- 0.01% frequency accuracy across the full test range
- 10.1" capacitive touchscreen, 1280 × 800, English UI
- Four-parameter measurement, freely selectable and shown together on one screen
- Three test modes: spot measurement, 201-point list sweep, graphical sweep
- High-power signal source: 20 Vrms / 100 mA
- Built-in ±40 V / 100 mA DC bias and 2 A current source (TH2840A/B)
- Graphical sweep with 4 selectable traces, 1/2/4-split-screen display
- 10-bin sorting comparator with fully programmable Handler interface
- SCPI and MODBUS standard
3 models, one platform
TH2840A
General-purpose bench testing
- Frequency
- 20 Hz – 500 kHz
- DC bias
- ±40 V / 100 mA
- Current source
- 0 – 2 A
- Impedance ranges
- 14
TH2840B
Extended range to 2 MHz
- Frequency
- 20 Hz – 2 MHz
- DC bias
- ±40 V / 100 mA
- Current source
- 0 – 2 A
- Impedance ranges
- 14
TH2840BL
High-frequency, GPIB-equipped
- Frequency
- 100 Hz – 2 MHz
- DC bias
- —
- Current source
- —
- Impedance ranges
- 20
TH2840BL adds GPIB as standard and expands to 20 impedance ranges, but omits the built-in DC bias source, current source and standalone RDC measurement of TH2840A/B. All three models share the same 10.1" touchscreen platform, four-parameter display, dual-CPU speed and SCPI/MODBUS command sets.
Applications
Passive components
Capacitors, inductors, magnetic cores, resistors, piezoelectric devices, transformers, chip components and network components.
Materials and semiconductors
Dielectric constant and loss angle of plastics/ceramics; permeability of ferrite and amorphous cores; C-V characteristics of semiconductors and liquid crystal cells.
Production and other components
Bin-sorted go/no-go inspection on component lines; impedance evaluation of PCBs, relays, switches, cables and batteries.
Industries and application examples
Technical specifications
| Parameter | TH2840A | TH2840B | TH2840BL |
|---|---|---|---|
| Display | 10.1" capacitive touchscreen, 1280 × 800, 16:9 | ||
| Measurement mode | Four parameters, freely selectable | ||
| AC parameters | Cp/Cs, Lp/Ls, Rp/Rs, |Z|, |Y|, R, X, G, B, θ, D, Q; VAC, IAC (TH2840A/B only) | ||
| DC parameters | RDC, VDC, IDC | RDC, VDC, IDC | — |
| Test frequency range | 20 Hz – 500 kHz | 20 Hz – 2 MHz | 100 Hz – 2 MHz |
| Frequency accuracy | 0.01% | ||
| AC voltage level | 5 mVrms – 20 Vrms | F ≤ 1 MHz: 5 – 20 Vrms; F > 1 MHz: 5 – 15 Vrms | F ≤ 1 MHz: 5 – 20 Vrms; F > 1 MHz: 5 – 15 Vrms |
| AC current level | 50 µArms – 100 mArms | 50 µArms – 100 mArms | 250 µArms – 100 mArms |
| RDC test voltage | 100 mV – 20 V | 100 mV – 20 V | — |
| DC bias voltage | 0 – ±40 V | 0 – ±40 V | — |
| DC bias current | 0 – ±100 mA | 0 – ±100 mA | — |
| Built-in current source | 0 – 2 A | 0 – 2 A | — |
| Output impedance | 30 Ω ±4% or 100 Ω ±2% @ 1 kHz, selectable | 30 Ω ±4% or 100 Ω ±2% @ 1 kHz, selectable | 20 Ω |
| Test terminal / cable | Five-terminal-pair, 0 m (1 m optional) | ||
| Impedance ranges | 14 ranges, 100 mΩ – 100 kΩ | 14 ranges, 100 mΩ – 100 kΩ | 20 ranges, 50 mΩ – 100 kΩ |
| Measurement speed | Fast+ 0.56 ms (1800 rdg/s), fast 3.3 ms, medium 90 ms, slow 220 ms | Fast+ 0.56 ms (1800 rdg/s), fast 3.3 ms, medium 90 ms, slow 220 ms | Fast 10 ms, medium 90 ms, slow 220 ms |
| Basic measurement accuracy | 0.05% (see the operation manual for details) | ||
| Measurement display range | Cs/Cp 0.00001 pF – 9.99999 F; Ls/Lp 0.00001 µH – 99.9999 kH; D 0.00001 – 9.99999; Q 0.00001 – 99999.9; R/X/Z/RDC 0.001 mΩ – 99.9999 MΩ; G/B/Y 0.00001 µS – 99.9999 S | ||
| Equivalent circuit | Series, parallel | ||
| Averaging / correction | 1 – 255 readings; open, short, load | ||
| List sweep | 201 points — frequency, AC V/I, DC bias V/I (100 mA), DC bias I (2 A) | 201 points — frequency, AC V/I, DC bias V/I (100 mA), DC bias I (2 A) | 201 points — frequency, AC V/I, DC bias current |
| Graphical sweep | 51/101/201/401/801 points, 1–4 traces, 1/2/4-split screen | ||
| Comparator / sorting | 10-bin + PASS/FAIL, tolerance or continuous mode, 0 – 99999 bin count | ||
| Data storage | Internal: approx. 100 MB non-volatile setting files. External USB: up to 8 GB | ||
| Warm-up time | 60 minutes | ||
| Power supply | 100–120 V AC / 198–242 V AC selectable, 47–63 Hz, ≥ 100 VA | ||
| Dimensions / weight | 430 × 177 × 265 mm (W × H × D), 11 kg | ||
Source: TH2840 Series Datasheet, Rev. 2026-09. Specifications subject to change without notice.
Interfaces
- RS232standard
- USB Hoststandard
- USB Devicestandard
- LANstandard
- Handlerstandard
- SCPI / MODBUSstandard
- GPIBstandard on TH2840BL only
- RS485optional (requires modification or an external RS232-to-RS485 converter)
Accessories
More fixtures are available on request from Techmize or your authorized distributor.
Photos of fixtures and accessories: click an item code above, or browse all accessories.
Downloads
Interested in the TH2840 Series?
Send us the model, quantity and your application. Our team in Ismaning will answer by email.