DC Electronic Loads

TH8300 Series

Modular Programmable DC Electronic Load, up to 2500 W

A modular, high-power DC electronic load platform for validating power supplies, chargers, battery packs and DC/DC converters. Choose a 5-slot (TH8300) or 2-slot (TH8310) mainframe and populate it with any combination of nine plug-in load modules (single- or dual-channel, 80 V or 600 V, from 100 W to 500 W) to match the exact test requirement, with up to ten channels and 2500 W in a single unit.

TH8300TH8310 CE

Technical question about this series? Ask our team.

Key features

  • Modular design; each module runs independently or under master/slave control
  • Up to 10 channels / 2500 W in one TH8300 mainframe; up to 400 A when modules are paralleled
  • High resolution, 0.1 mV / 10 µA class
  • Dynamic load frequency up to 50 kHz; sampling up to 500 kHz
  • Four standard modes (CC, CR, CV, CP) plus 12 advanced test modes
  • 2.8" 24-bit colour LCD per module; English user interface
  • Module parallel / master-slave linking (Power mode or Copy mode)
  • Data logging, 40 setting files per module, timing and power-on-hold functions
  • Protections: OVP, OCP, OPP, OTP, reverse polarity (REV), low voltage (LVP); short-circuit test mode
  • RS232, USB Host, USB Device, LAN, GPIB and SYSTEM I/O, all standard

2 models, one platform

TH8300

5-slot mainframe

Module slots
5
Max. channels
10
Max. unit power
2500 W (5 × 500 W modules)
Frame size
477 × 177 × 590 mm
Frame weight
15 kg
Request a quote for TH8300

TH8310

2-slot mainframe

Module slots
2
Max. channels
4
Max. unit power
—
Frame size
255 × 177 × 590 mm
Frame weight
10.5 kg
Request a quote for TH8310

TH8300 and TH8310 are sold as empty mainframes; load modules are ordered and installed separately. All modules measure 85.5 × 142 × 550 mm and weigh 4.2 kg.

Load modules

ModuleChannelsPowerInput voltageInput currentMin. operating voltage
TH8301-80-202100 W × 20–80 V0–20 A / ch0.5 V @ 0.2 A
TH8301A-80-202200 W × 20–80 V0–20 A / ch0.5 V @ 0.2 A
TH8302-80-401200 W0–80 V0–40 A0.5 V @ 0.4 A
TH8303-80-601300 W0–80 V0–60 A0.5 V @ 0.6 A
TH8304-80-801400 W0–80 V0–80 A0.4 V @ 0.8 A
TH8305-80-801500 W0–80 V0–80 A0.4 V @ 0.8 A
TH8302-600-101200 W0–600 V0–10 A2 V @ 0.1 A
TH8303-600-151300 W0–600 V0–15 A2 V @ 0.15 A
TH8305-600-301500 W0–600 V0–30 A2 V @ 0.3 A

Min. operating voltage is the lowest input voltage at which the module can still sink its full rated current.

Applications

Power supplies

Chargers, switching power supplies, communication power supplies, LED drivers, mobile-phone batteries, power banks.

New energy

Solar cells and modules, EV power systems, electric bicycles.

Power components

Fuses, connectors, relays, sensors and other electronic power components.

Automation and integration

Multi-channel automated test cells built around the modular mainframe.

Technical specifications

ParameterTH8300TH8310
CV ranges / resolution 80 V modules: 6 V / 0.1 mV · 16 V / 1 mV · 80 V / 1 mV · 600 V modules: 80 V / 1 mV · 150 V / 10 mV · 600 V / 10 mV
CV accuracy 0.05% + 0.1% FS
CC ranges Three ranges per module, e.g. 0–0.2 A / 0–2 A / 0–20 A on TH8301-80-20
CC resolution 80 V modules: 0.01 mA / 0.1 mA / 1 mA · 600 V modules: 0.005 mA / 0.05 mA / 0.5 mA
CC accuracy 0.2% + 0.2% FS
CR range, TH8301-80-20 / TH8301A-80-20 0.04–80 Ω (6 V) · 1.4–2.9 kΩ (16 V) · 6–12 kΩ (80 V)
CR range, TH8302-80-40 0.03–60 Ω (6 V) · 1.0–2.16 kΩ (16 V) · 4.3–9 kΩ (80 V)
CR range, TH8303-80-60 0.015–30 Ω (6 V) · 0.3–600 Ω (16 V) · 1.5–3 kΩ (80 V)
CR range, TH8304-80-80 0.01–20 Ω (6 V) · 0.36–720 Ω (16 V) · 1.5–2.9 kΩ (80 V)
CR range, TH8305-80-80 0.01–20 Ω (6 V) · 0.3–720 Ω (16 V) · 1.5–2.9 kΩ (80 V)
CR range, TH8302-600-10 0.2–400 Ω (80 V) · 3–6 kΩ (150 V) · 300–300 kΩ (600 V)
CR range, TH8303-600-15 0.13–270 Ω (80 V) · 1.9–4 kΩ (150 V) · 208–200 kΩ (600 V)
CR range, TH8305-600-30 0.1–200 Ω (80 V) · 1.5–3 kΩ (150 V) · 150–150 kΩ (600 V)
CR resolution / accuracy 0.1 Ω (80 V modules) / 1 Ω (600 V modules); 1% (not below 5% of the current measurement range)
CP ranges Three ranges per module, up to the module's rated power (e.g. 0–10 W / 0–50 W / 0–500 W on TH8305-80-80)
CP accuracy 1%
Dynamic mode 100 Hz – 50 kHz / 0.01 Hz – 1 kHz, accuracy 1 µs/1 ms + 100 ppm; duty cycle 1–99%; min. working voltage 1.5 V (80 V) / 3 V (600 V)
Slew rate Up to 16 A/ms (0.08–8 A/µs) on TH8304/TH8305-80-80; slew accuracy 10% ± 20 µs, min. rise time 10 µs
Voltage readback accuracy 80 V modules: 0.025% + 0.01% FS (6 V / 16 V), 0.01% + 0.025% FS (80 V) · 600 V modules: 0.025% + 0.01% FS (80 V / 150 V), 0.01% + 0.025% FS (600 V)
Current / power readback accuracy 0.2% + 0.2% FS
Advanced modes DYN, SWP, CR-LED, BATT, TIMING, MPPT, OCPT, OVPT, OPPT, SINE, LIST, AUTO
Module protections OVP · OCP · OPP · OTP (per module)
Module link modes Power mode (current shared in proportion to each module's rating) · Copy mode (all linked modules follow the master's set current)
Setting storage 40 setting groups (50 status-memory groups)
Power supply (mainframe) 90–130 VAC or 175–253 VAC, 47–63 Hz, < 300 VA
Operating temperature 0–40 °C

Source: TH8300 Series Datasheet, Rev. 2026-09. Specifications subject to change without notice.

Interfaces

  • RS232standard
  • USB Hoststandard
  • USB Devicestandard
  • LANstandard
  • GPIBstandard
  • SYSTEM I/Ostandard
  • SCPIstandard

Accessories

Standard accessories

ItemDescription
—EU power cable (Schuko, CEE 7/7)

Optional test fixtures

ItemDescription
TH26035DTest cable
TH26035ETest cable
TH2608126-pin analog control interface

More cables and fixtures are available on request from Techmize or your authorized distributor.

Photos of fixtures and accessories: click an item code above, or browse all accessories.

Downloads

Interested in the TH8300 Series?

Send us the model, quantity and your application. Our team in Ismaning will answer by email.

Request a quote