TH8300 Series
Modular Programmable DC Electronic Load, up to 2500 W
A modular, high-power DC electronic load platform for validating power supplies, chargers, battery packs and DC/DC converters. Choose a 5-slot (TH8300) or 2-slot (TH8310) mainframe and populate it with any combination of nine plug-in load modules (single- or dual-channel, 80 V or 600 V, from 100 W to 500 W) to match the exact test requirement, with up to ten channels and 2500 W in a single unit.
Technical question about this series? Ask our team.
Key features
- Modular design; each module runs independently or under master/slave control
- Up to 10 channels / 2500 W in one TH8300 mainframe; up to 400 A when modules are paralleled
- High resolution, 0.1 mV / 10 µA class
- Dynamic load frequency up to 50 kHz; sampling up to 500 kHz
- Four standard modes (CC, CR, CV, CP) plus 12 advanced test modes
- 2.8" 24-bit colour LCD per module; English user interface
- Module parallel / master-slave linking (Power mode or Copy mode)
- Data logging, 40 setting files per module, timing and power-on-hold functions
- Protections: OVP, OCP, OPP, OTP, reverse polarity (REV), low voltage (LVP); short-circuit test mode
- RS232, USB Host, USB Device, LAN, GPIB and SYSTEM I/O, all standard
2 models, one platform
TH8300
5-slot mainframe
- Module slots
- 5
- Max. channels
- 10
- Max. unit power
- 2500 W (5 × 500 W modules)
- Frame size
- 477 × 177 × 590 mm
- Frame weight
- 15 kg
TH8310
2-slot mainframe
- Module slots
- 2
- Max. channels
- 4
- Max. unit power
- —
- Frame size
- 255 × 177 × 590 mm
- Frame weight
- 10.5 kg
TH8300 and TH8310 are sold as empty mainframes; load modules are ordered and installed separately. All modules measure 85.5 × 142 × 550 mm and weigh 4.2 kg.
Load modules
| Module | Channels | Power | Input voltage | Input current | Min. operating voltage |
|---|---|---|---|---|---|
| TH8301-80-20 | 2 | 100 W × 2 | 0–80 V | 0–20 A / ch | 0.5 V @ 0.2 A |
| TH8301A-80-20 | 2 | 200 W × 2 | 0–80 V | 0–20 A / ch | 0.5 V @ 0.2 A |
| TH8302-80-40 | 1 | 200 W | 0–80 V | 0–40 A | 0.5 V @ 0.4 A |
| TH8303-80-60 | 1 | 300 W | 0–80 V | 0–60 A | 0.5 V @ 0.6 A |
| TH8304-80-80 | 1 | 400 W | 0–80 V | 0–80 A | 0.4 V @ 0.8 A |
| TH8305-80-80 | 1 | 500 W | 0–80 V | 0–80 A | 0.4 V @ 0.8 A |
| TH8302-600-10 | 1 | 200 W | 0–600 V | 0–10 A | 2 V @ 0.1 A |
| TH8303-600-15 | 1 | 300 W | 0–600 V | 0–15 A | 2 V @ 0.15 A |
| TH8305-600-30 | 1 | 500 W | 0–600 V | 0–30 A | 2 V @ 0.3 A |
Min. operating voltage is the lowest input voltage at which the module can still sink its full rated current.
Applications
Power supplies
Chargers, switching power supplies, communication power supplies, LED drivers, mobile-phone batteries, power banks.
New energy
Solar cells and modules, EV power systems, electric bicycles.
Power components
Fuses, connectors, relays, sensors and other electronic power components.
Automation and integration
Multi-channel automated test cells built around the modular mainframe.
Technical specifications
| Parameter | TH8300 | TH8310 |
|---|---|---|
| CV ranges / resolution | 80 V modules: 6 V / 0.1 mV · 16 V / 1 mV · 80 V / 1 mV · 600 V modules: 80 V / 1 mV · 150 V / 10 mV · 600 V / 10 mV | |
| CV accuracy | 0.05% + 0.1% FS | |
| CC ranges | Three ranges per module, e.g. 0–0.2 A / 0–2 A / 0–20 A on TH8301-80-20 | |
| CC resolution | 80 V modules: 0.01 mA / 0.1 mA / 1 mA · 600 V modules: 0.005 mA / 0.05 mA / 0.5 mA | |
| CC accuracy | 0.2% + 0.2% FS | |
| CR range, TH8301-80-20 / TH8301A-80-20 | 0.04–80 Ω (6 V) · 1.4–2.9 kΩ (16 V) · 6–12 kΩ (80 V) | |
| CR range, TH8302-80-40 | 0.03–60 Ω (6 V) · 1.0–2.16 kΩ (16 V) · 4.3–9 kΩ (80 V) | |
| CR range, TH8303-80-60 | 0.015–30 Ω (6 V) · 0.3–600 Ω (16 V) · 1.5–3 kΩ (80 V) | |
| CR range, TH8304-80-80 | 0.01–20 Ω (6 V) · 0.36–720 Ω (16 V) · 1.5–2.9 kΩ (80 V) | |
| CR range, TH8305-80-80 | 0.01–20 Ω (6 V) · 0.3–720 Ω (16 V) · 1.5–2.9 kΩ (80 V) | |
| CR range, TH8302-600-10 | 0.2–400 Ω (80 V) · 3–6 kΩ (150 V) · 300–300 kΩ (600 V) | |
| CR range, TH8303-600-15 | 0.13–270 Ω (80 V) · 1.9–4 kΩ (150 V) · 208–200 kΩ (600 V) | |
| CR range, TH8305-600-30 | 0.1–200 Ω (80 V) · 1.5–3 kΩ (150 V) · 150–150 kΩ (600 V) | |
| CR resolution / accuracy | 0.1 Ω (80 V modules) / 1 Ω (600 V modules); 1% (not below 5% of the current measurement range) | |
| CP ranges | Three ranges per module, up to the module's rated power (e.g. 0–10 W / 0–50 W / 0–500 W on TH8305-80-80) | |
| CP accuracy | 1% | |
| Dynamic mode | 100 Hz – 50 kHz / 0.01 Hz – 1 kHz, accuracy 1 µs/1 ms + 100 ppm; duty cycle 1–99%; min. working voltage 1.5 V (80 V) / 3 V (600 V) | |
| Slew rate | Up to 16 A/ms (0.08–8 A/µs) on TH8304/TH8305-80-80; slew accuracy 10% ± 20 µs, min. rise time 10 µs | |
| Voltage readback accuracy | 80 V modules: 0.025% + 0.01% FS (6 V / 16 V), 0.01% + 0.025% FS (80 V) · 600 V modules: 0.025% + 0.01% FS (80 V / 150 V), 0.01% + 0.025% FS (600 V) | |
| Current / power readback accuracy | 0.2% + 0.2% FS | |
| Advanced modes | DYN, SWP, CR-LED, BATT, TIMING, MPPT, OCPT, OVPT, OPPT, SINE, LIST, AUTO | |
| Module protections | OVP · OCP · OPP · OTP (per module) | |
| Module link modes | Power mode (current shared in proportion to each module's rating) · Copy mode (all linked modules follow the master's set current) | |
| Setting storage | 40 setting groups (50 status-memory groups) | |
| Power supply (mainframe) | 90–130 VAC or 175–253 VAC, 47–63 Hz, < 300 VA | |
| Operating temperature | 0–40 °C | |
Source: TH8300 Series Datasheet, Rev. 2026-09. Specifications subject to change without notice.
Interfaces
- RS232standard
- USB Hoststandard
- USB Devicestandard
- LANstandard
- GPIBstandard
- SYSTEM I/Ostandard
- SCPIstandard
Accessories
Standard accessories
| Item | Description |
|---|---|
| — | EU power cable (Schuko, CEE 7/7) |
More cables and fixtures are available on request from Techmize or your authorized distributor.
Photos of fixtures and accessories: click an item code above, or browse all accessories.
Downloads
Interested in the TH8300 Series?
Send us the model, quantity and your application. Our team in Ismaning will answer by email.