TH6900 Series
Wide-Range Programmable DC Power Supply, 0–1000 V
A constant-power, wide-voltage-range programmable DC power supply for R&D, production-line test and new-energy applications. 21 models across three power classes (750 W, 1.5 kW, 3 kW) cover output voltages from 35 V to 1000 V. Each model delivers up to three times the voltage/current range of an equal-power fixed-rectangle supply, so fewer models are needed to cover a broad test-voltage window. CV / CC / CP operation, up to 10-unit true master-slave parallel operation, a built-in sequence test and function generator, and a solar-array simulation mode are standard across the series.
Technical question about this series? Ask our team.
Key features
- 0–1000 V output, 21 models across three power ratings (750 W / 1.5 kW / 3 kW)
- High-frequency LLC multi-resonant inverter; efficiency up to 93%, active PFC up to 0.99
- CV, CC and CP operating modes with adjustable rise/fall edge speed (0.01–999.99 s)
- True master-slave parallel operation with active current sharing, up to 10 units of the same model
- Built-in function generator (sine, square, triangle, trapezoid) and 50-sequence / 20-step sequence test
- Built-in solar-array simulation mode, plus CC / CV / EN50530 output via PC software
- Discharge circuit brings output below 10 V within 1 s at no-load / light load
- 4.0" high-brightness colour LCD, English UI; remote sense (S+/S–)
- OVP, OCP, OPP, OTP, input under-voltage and SENSE reverse-connection protection
- SCPI command support; RS232 standard (RS485 or CAN as a factory-fitted alternative)
21 models, one platform
| Model | Power | Voltage | Current | Net weight | Quote |
|---|---|---|---|---|---|
| TH6940-60 | 750 W | 0 – 40 V | 0 – 60 A | 9.6 kg | Quote |
| TH6980-30 | 750 W | 0 – 80 V | 0 – 30 A | 9.6 kg | Quote |
| TH69200-12.5 | 750 W | 0 – 200 V | 0 – 12.5 A | 9.6 kg | Quote |
| TH69360-7.5 | 750 W | 0 – 360 V | 0 – 7.5 A | 9.6 kg | Quote |
| TH69500-5 | 750 W | 0 – 500 V | 0 – 5 A | 9.6 kg | Quote |
| TH69750-3 | 750 W | 0 – 750 V | 0 – 3 A | 9.6 kg | Quote |
| TH691000-2.5 | 750 W | 0 – 1000 V | 0 – 2.5 A | 9.6 kg | Quote |
| TH6935-100 | 1.5 kW | 0 – 35 V | 0 – 100 A | 10.8 kg | Quote |
| TH6980-60 | 1.5 kW | 0 – 80 V | 0 – 60 A | 10.8 kg | Quote |
| TH69200-25 | 1.5 kW | 0 – 200 V | 0 – 25 A | 10.8 kg | Quote |
| TH69360-15 | 1.5 kW | 0 – 360 V | 0 – 15 A | 10.8 kg | Quote |
| TH69500-10 | 1.5 kW | 0 – 500 V | 0 – 10 A | 10.8 kg | Quote |
| TH69750-6 | 1.5 kW | 0 – 750 V | 0 – 6 A | 10.8 kg | Quote |
| TH691000-5 | 1.5 kW | 0 – 1000 V | 0 – 5 A | 10.8 kg | Quote |
| TH6935-200 | 3 kW | 0 – 35 V | 0 – 200 A | 13.5 kg | Quote |
| TH6980-120 | 3 kW | 0 – 80 V | 0 – 120 A | 13.5 kg | Quote |
| TH69200-50 | 3 kW | 0 – 200 V | 0 – 50 A | 13.5 kg | Quote |
| TH69360-30 | 3 kW | 0 – 360 V | 0 – 30 A | 13.5 kg | Quote |
| TH69500-20 | 3 kW | 0 – 500 V | 0 – 20 A | 13.5 kg | Quote |
| TH69750-12 | 3 kW | 0 – 750 V | 0 – 12 A | 13.5 kg | Quote |
| TH691000-10 | 3 kW | 0 – 1000 V | 0 – 10 A | 13.5 kg | Quote |
All 21 models share the same 2U chassis, control panel, protection set and interface options; only rated voltage, current and power differ. Select the model whose voltage/current pair covers your test point.
Efficiency and ripple by voltage class
| Voltage class | Efficiency | Ripple RMS (20 Hz – 300 kHz) | Ripple p-p (20 Hz – 2 MHz) |
|---|---|---|---|
| 40 V | ≤ 92% | 10 mVrms | 75 mVpp |
| 80 V | ≤ 92% | 10 mVrms | 100 mVpp |
| 200 V | ≤ 92% | 20 mVrms | 175 mVpp |
| 360 V | ≤ 93% | 40 mVrms | 250 mVpp |
| 500 V | ≤ 93% | 50 mVrms | 325 mVpp |
| 750 V | ≤ 93% | 75 mVrms | 500 mVpp |
| 1000 V | ≤ 93% | 100 mVrms | 650 mVpp |
Applications
New energy and e-mobility
Solar-cell and PV-array simulation, new-energy vehicle and e-bike component test, battery-pack charging and burn-in.
R&D and production test
General R&D and design-verification testing, automated test-cell integration, LED test.
Production line and education
Routine test and maintenance on production-line workbenches, teaching laboratories.
Technical specifications
| Parameter | TH6940-60 | TH6980-30 | TH69200-12.5 | TH69360-7.5 | TH69500-5 | TH69750-3 | TH691000-2.5 | TH6935-100 | TH6980-60 | TH69200-25 | TH69360-15 | TH69500-10 | TH69750-6 | TH691000-5 | TH6935-200 | TH6980-120 | TH69200-50 | TH69360-30 | TH69500-20 | TH69750-12 | TH691000-10 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Operating modes | Constant voltage (CV), constant current (CC), constant power (CP) | ||||||||||||||||||||
| Set-value and readback accuracy | Voltage ≤ ±(0.05% + 0.04% FS) · Current ≤ ±(0.15% + 0.1% FS) · Power ≤ ±0.8% FS | ||||||||||||||||||||
| Resolution | Voltage 10 mV on every model; current 1 mA on the lower-current model at each voltage, 10 mA on the higher-current models | ||||||||||||||||||||
| Load regulation | Voltage ≤ 0.05% FS (0–100% load) · Current ≤ 0.15% FS (0–100% ΔUDC) | ||||||||||||||||||||
| Line regulation | Voltage ≤ 0.02% FS · Current ≤ 0.05% FS (both at ±10% ΔUAC input) | ||||||||||||||||||||
| Rise time | ≤ 2 ms, 10–100% no load · ≤ 30 ms, 10–90% full load | ||||||||||||||||||||
| Rise/fall edge speed | Adjustable in all modes (CV/CC/CP), 0.01–999.99 s | ||||||||||||||||||||
| Protection | OTP, OVP, OCP, OPP, PF (input under-voltage), SENSE reverse-connection protection | ||||||||||||||||||||
| OVP range | Adjustable, 0–110% of rated output voltage | ||||||||||||||||||||
| Discharge circuit | Brings output below 10 V within 1 s at no-load/light-load shutdown | ||||||||||||||||||||
| Master-slave parallel | True master-slave operation via shared digital bus, up to 10 units of the same model, active current sharing | ||||||||||||||||||||
| Sequence test | 50 sequences (non-volatile), 20 steps per sequence, 12 configurable step functions including loop control and slope-mode output | ||||||||||||||||||||
| Function generator | Sine, square, triangle and trapezoidal waveforms on output voltage or current | ||||||||||||||||||||
| Solar-array simulation | Built-in output-curve model; CC, CV and EN50530 modes also available via host-computer software | ||||||||||||||||||||
| Remote sense | S+/S– terminals for output-voltage compensation at the load | ||||||||||||||||||||
| Display | 4.0" high-brightness colour LCD, English UI | ||||||||||||||||||||
| Cooling | Temperature-controlled fans | ||||||||||||||||||||
| Operating conditions | Indoor use; 0–50 °C, < 80% RH non-condensing, altitude < 2000 m | ||||||||||||||||||||
| Storage temperature | –20 to 70 °C | ||||||||||||||||||||
| AC input | 220 V AC ±10%, 45–66 Hz, 1ph+N+PE, power factor ≥ 0.99 | ||||||||||||||||||||
| Isolation withstand voltage | AC input to chassis: 2500 VDC · AC input to DC output: 2500 VDC · DC output to chassis (PE): negative max. 400 VDC, positive max. 400 VDC + output voltage | ||||||||||||||||||||
| Dimensions (W × H × D) | 482 × 88 × 455 mm, standard 2U rack chassis | ||||||||||||||||||||
| Net weight | 9.6 kg (750 W) / 10.8 kg (1.5 kW) / 13.5 kg (3 kW) | ||||||||||||||||||||
Source: TH6900 Series Datasheet, Rev. 2026-09. Specifications subject to change without notice.
Interfaces
- RS232standard
- USB Hoststandard
- SCPIstandard
- RS485factory alternative to RS232
- CANfactory alternative to RS232
- PAR IN / PAR OUTmaster-slave bus
Accessories
Standard accessories
| Item | Description |
|---|---|
| — | EU power cable (Schuko, CEE 7/7) |
RS232, RS485 and CAN share one communication port and are factory-fitted as one choice per unit. GPIB, LAN and an analog control interface are not available on this series. Ask Techmize for wire-gauge guidance at high current ratings (up to 200 A).
Photos of fixtures and accessories: click an item code above, or browse all accessories.
Downloads
Interested in the TH6900 Series?
Send us the model, quantity and your application. Our team in Ismaning will answer by email.