TH2848 Series
Precision Impedance Analyzer, 4 Hz – 10 MHz
A new-generation precision impedance analyzer built on wideband auto-zero automatic-balancing-bridge technology and a dual-CPU / Linux platform. Its 10.1" capacitive touchscreen shows all four measurement parameters, sorting bins and status at once, with spot, list-sweep and graphic-sweep test modes, plus built-in piezoelectric admittance-circle and dielectric-constant testing.
Technical question about this series? Ask our team.
Key features
- 10.1" capacitive touchscreen, 1280 × 800 resolution
- 0.05% basic accuracy, automatic balancing bridge, 4-terminal-pair test
- 15 range configurations for high stability and consistency
- Signal source: 20 VAC / 100 mAAC, DC bias ±40 VDC / 100 mADC
- Dual-CPU, test speed up to 400 readings/s (2.5 ms)
- Spot, 201-point list-sweep and graphic-sweep (1–4 traces, 1/2/4-split)
- Four-parameter display; one-touch screenshot and data recording
- Built-in piezoelectric admittance-circle and dielectric-constant test
- 10-bin comparator; graphic-sweep mode supports curve-condition sorting
- SCPI and MODBUS command sets
4 models, one platform
TH2848-02L
Entry-level, reduced signal source
- Frequency
- 4 Hz – 2 MHz
- Basic accuracy
- 0.05%
- AC level
- 5 mV – 2 V
- DC bias
- 0–±10 V
TH2848-02
Full-power, 2 MHz
- Frequency
- 4 Hz – 2 MHz
- Basic accuracy
- 0.05%
- AC level
- 5 mV – 20 V
- DC bias
- 0–±40 V
TH2848-05
Full-power, 5 MHz
- Frequency
- 4 Hz – 5 MHz
- Basic accuracy
- 0.05%
- AC level
- 5 mV – 20 V
- DC bias
- 0–±40 V
TH2848-10
Top model, widest frequency range
- Frequency
- 4 Hz – 10 MHz
- Basic accuracy
- 0.05%
- AC level
- 5 mV – 20 V
- DC bias
- 0–±40 V
TH2848-02L shares the 4 Hz – 2 MHz frequency range of TH2848-02 but has a lower-power AC signal source (5 mV – 2 V / 0 – 20 mA) and a reduced ±10 V DC bias range. TH2848-02/05/10 share the same 5 mV – 20 V / 0 – 100 mA signal source and ±40 V DC bias, and differ only in maximum test frequency.
Applications
Passive and other components
Capacitors, inductors, cores, resistors, piezoelectric devices, transformers, chip assemblies, crystals; PCBs, relays, switches, cables, batteries.
Semiconductors and materials
LED driver IC parasitics, varactor-diode C-VDC, transistor/IC parasitic analysis; dielectric constant and C-V properties of semiconductor and liquid-crystal materials.
Dielectric, magnetic and piezoelectric
Dielectric constant/loss of plastics and ceramics; permeability/loss of ferrites; piezoceramic filters, transformers and transducers — capacitance, resonance frequency, coupling coefficient.
Industries and application examples
Technical specifications
| Parameter | TH2848-02L | TH2848-02 | TH2848-05 | TH2848-10 |
|---|---|---|---|---|
| Display | 10.1" capacitive touchscreen, 16:9, 1280 × 800 | |||
| Measured parameters | Four parameters, freely selectable. AC: Cp, Cs, Lp, Ls, Rp, Rs, |Z|, |Y|, R, X, G, B, θ, D, Q, VAC, IAC. DC: RDC | |||
| Piezoelectric parameters | Ct, Dt, Fs, Fp, Fp-Fs, Zmin, Zmax, F1, F2, F2-F1, Gmax, C0, C1, R1, L, Kp, Keff, Kt, K31, K33, Qm, ε, εr | |||
| Dielectric parameters | Cp, D, ε, |ε|, εr', εr'', tanδ, Q | |||
| Test frequency range | 4 Hz – 2 MHz | 4 Hz – 2 MHz | 4 Hz – 5 MHz | 4 Hz – 10 MHz |
| Frequency accuracy / resolution | 0.01% accuracy; resolution 0.1 mHz (< 100 Hz), 1 mHz (100 Hz – 1 kHz), 10 mHz (1 – 10 kHz), 100 mHz (10 – 100 kHz), 1 Hz (100 kHz – 1 MHz), 10 Hz (1 – 10 MHz) | |||
| AC signal level | TH2848-02L: 5 mVrms – 2 Vrms, 0 – 20 mArms. TH2848-02/05/10: 5 mVrms – 20 Vrms (F ≤ 1 MHz) / 15 V (1 – 2 MHz) / 2 V (2 – 5 MHz) / 1 V (5 – 10 MHz), 0 – 100 mArms | |||
| Basic / max. accuracy | 0.05% / 0.05% (see the operation manual for the detailed accuracy chart) | |||
| RDC test signal | 100 mV – 1 V, 100 µV resolution | |||
| DC bias voltage | 0 – ±10 V | 0 – ±40 V | 0 – ±40 V | 0 – ±40 V |
| DC bias current / accuracy | 0 – ±100 mA (all models); 1% × setting + 5 mV (AC ≤ 2 V) / 2% × setting + 8 mV (AC > 2 V) | |||
| Independent voltage source | −10 V – 10 V, 1 mV resolution; −45 mA – +45 mA; output impedance 100 Ω | |||
| Test configuration | Four-terminal pair, 0 m / 1 m cable; output impedance 100 Ω ±1% @ 1 kHz; series/parallel equivalent circuit | |||
| Correction / averaging | Open, short, load correction; 1 – 255 reading average | |||
| Range selection | AUTO, HOLD — 15 ranges (LCR: 100 mΩ – 100 kΩ; RDC: 10 Ω – 100 kΩ) | |||
| Trigger / speed | Continuous, single, delay 0 – 60 s; fast 2.5 ms / medium 90 ms / slow 220 ms (≥ 100 kHz) | |||
| List sweep | 201 points — frequency, AC V/I, DC bias V/I, with dielectric-constant testing; SEQ/STEP trigger modes | |||
| Graphic sweep | 51/101/201/401/801 points; 1–4 traces, 1/2/4-split; log/linear; built-in piezoelectric admittance-circle test | |||
| Comparator | 10-bin + PASS/FAIL, deviation/% deviation limits, tolerance/continuous mode, count 0 – 99999 | |||
| Special functions | Independent 24 V cylinder control (0 – 60 s); one-touch screenshot/recording; embedded help | |||
| Storage | Internal approx. 6 GB user space; external USB for setup files, screenshots and log files | |||
| Warm-up / power supply | 60 min warm-up; 220–240 V AC (European configuration), 47–63 Hz, ≥ 130 VA. Other supply voltages on request. | |||
| Dimensions / weight | 430 × 177 × 265 mm (W × H × D), 11 kg | |||
Source: TH2848 Series Datasheet, Rev. 2026-09. Specifications subject to change without notice.
Interfaces
- RS232standard
- USB Hoststandard (2 ports)
- USB Devicestandard
- LANstandard, 10/100 M
- Handlerstandard
- GPIBstandard
- RS485standard
- External DC biasstandard
- SCPI / MODBUSstandard
Accessories
More fixtures and custom clamp configurations are available on request from Techmize or your authorized distributor.
Photos of fixtures and accessories: click an item code above, or browse all accessories.
Downloads
Interested in the TH2848 Series?
Send us the model, quantity and your application. Our team in Ismaning will answer by email.