TH2840X Series
Automatic Transformer Test System, up to 2 MHz
A dual-CPU, embedded-Linux test system developed as a functional extension of the TH2840 platform and optimized for transformer testing. A 10.1" capacitive touchscreen with graphical pin-association mapping puts winding setup, scan conditions and pass/fail limits on a single page — for switching-transformer and network-transformer scanning, balun/isolation-transformer testing, multi-channel DCR scanning and passive-component and impedance-network analysis.
Technical question about this series? Ask our team.
Key features
- Dual-CPU architecture, embedded Linux; touch, mouse and keyboard operation, built-in help
- 10.1" 1280 × 800 capacitive touchscreen; up to 288 test pins on TH2840NX
- Test speed up to 1800 readings/s (0.56 ms Fast+, ≥ 2 kHz); electronic range switching, no relay noise or wear
- Test level up to 20 Vrms; built-in DC bias ±40 V / ±100 mA, internal current source to 2 A
- Graphical pin-association mapping page for winding setup
- Lk (leakage inductance) setup entered directly at each winding pin
- Balance scan with 10 points
- Single-page setup for all transformer test conditions and series/parallel pin wiring
- SCPI and MODBUS standard; RS232, LAN, 2 × USB Host, USB Device, Handler and external DC-bias control standard
- Optional TH2840X-LCR module adds full four-parameter LCR bridge measurement
3 models, one platform
TH2840AX
Compact bench platform, 20-pin scanning
- Frequency
- 20 Hz – 500 kHz
- Test pins
- 20 (TH1901)
- Enclosure
- 430 × 177 × 265 mm
- Weight
- 11 kg
TH2840BX
Same enclosure, extended to 2 MHz
- Frequency
- 20 Hz – 2 MHz
- Test pins
- 20 (TH1901)
- Enclosure
- 430 × 177 × 265 mm
- Weight
- 11 kg
TH2840NX
Deep chassis, internal scan board to 288 pins
- Frequency
- 20 Hz – 500 kHz
- Test pins
- 48 – 288
- Enclosure
- 430 × 177 × 405 mm
- Weight
- 17 kg
TH2840AX and TH2840BX share an identical 265 mm-deep enclosure and connect to the DUT through the external TH1901 scan fixture (20 pins). TH2840NX uses a deeper 405 mm chassis with an internal 48-pin scan board, expandable in 48-pin steps (up to six boards) to 288 pins. All three models support the optional TH2840X-LCR bridge function and ship with SCPI/MODBUS as standard. The standard TH2840X does not include a standalone LCR-meter function; order the TH2840X-LCR option for complete four-parameter LCR measurement.
Applications
Transformers and inductive components
Switching-transformer and network-transformer scanning with comprehensive characteristic analysis; balun and isolation-transformer testing.
Discrete passives and relays
Multi-channel scanning of discrete L, R and C components; relay drive-coil and contact-resistance multi-channel testing.
Production integration
Multi-channel DCR scanning; impedance-network analysis; Handler-based bin sorting for automated test cells.
Industries and application examples
Technical specifications
| Parameter | TH2840AX | TH2840BX | TH2840NX |
|---|---|---|---|
| Display | 10.1" capacitive touchscreen, 1280 × 800, 16:9 | ||
| Test pins | 20 (via TH1901 scan box) | 20 (via TH1901 scan box) | 48 – 288 (48 × 6 internal boards) |
| Frequency range | 20 Hz – 500 kHz | 20 Hz – 2 MHz | 20 Hz – 500 kHz |
| Frequency accuracy | 0.01% | ||
| Frequency resolution | 0.1 mHz (20 – 99.9999 Hz), 1 mHz (100 – 999.999 Hz), 10 mHz (1 – 9.99999 kHz), 100 mHz (10 – 99.9999 kHz), 1 Hz (100 – 999.999 kHz), 10 Hz (1 – 2 MHz, BX only) | ||
| AC test signal mode | Rated value (ALC OFF): set voltage = open-circuit Hcur voltage, set current = short-circuit Hcur current. Constant value (ALC ON): holds DUT voltage/current at the set value | ||
| Test voltage range | 5 mVrms – 20 Vrms | 5 mVrms – 20 Vrms (≤ 1 MHz) / 5 mVrms – 15 Vrms (> 1 MHz) | 5 mVrms – 20 Vrms |
| Test voltage accuracy | ±(10% × setting + 2 mV) (AC ≤ 2 Vrms); ±(10% × setting + 5 mV) (AC > 2 Vrms) | ||
| Test current range | 50 µArms – 100 mArms | ||
| RDC test signal | Voltage 100 mV – 20 V (1 mV / 10 mV res.); current 0 – 100 mA (10 µA / 100 µA res.) | ||
| DC bias | Voltage 0 – ±40 V (1 mV / 10 mV res.); current 0 – ±100 mA (10 µA / 100 µA res.) | ||
| Built-in current source | 0 – 2 A, accuracy ±(2% × setting + 2 mA) at I > 5 mA, 1 mA resolution | ||
| Output impedance | 30 Ω ±4% @ 1 kHz or 100 Ω ±2% @ 1 kHz, selectable | ||
| Transformer test parameters | Cs/Cp, Ls/Lp, DCR, Zx, Rs/Rp, D, Q, dZ (phase angle), Lk (leakage inductance), phase, balance, turns ratio (Ns:Np = U2/U1), turns (Ns = Np × U2/U1) | ||
| Transformer test mode | Continuous: one trigger measures all set parameters. Step: one trigger per parameter | ||
| Transformer measurement speed | Fast+ 1 ms (> 10 kHz), fast 3.3 ms, medium 90 ms, slow 220 ms | ||
| Averaging / delay | Each test parameter has independent averaging (0 – 255 readings) and independent delay time | ||
| Internal scan board | None — external TH1901 scan box | None — external TH1901 scan box | 1 board standard, expandable to 6 (24 × 2 pins per board, 288 pins max.) |
| Handler pin definition | NS1–NS9, GOOD, NG, TEST, TRIGGER, RESET | NS1–NS9, GOOD, NG, TEST, TRIGGER, RESET | NS1–NS30, GOOD, NG, TEST, TRIGGER, RESET |
| Windings | Primary up to 60, secondary up to 9 | ||
| Test lead interface | 25 × 2-pin FRC socket | ||
| External scan box | Compatible with TH1901 series, TH1831 | ||
| LCR function (optional TH2840X-LCR) | Cp/Cs, Lp/Ls, Rp/Rs, |Z|, |Y|, R, X, G, B, θ, D, Q (AC); RDC, VDC, IDC (DC), any 4 parameters simultaneously; 0.05% basic accuracy; fast+ 0.56 ms, fast 3.3 ms, medium 90 ms, slow 220 ms | ||
| Storage | Internal approx. 100 MB non-volatile memory, up to 500 setting files; USB for settings, screenshots, log files | ||
| External DC bias control | TH1778A, up to 6 units / 120 A | ||
| Power / warm-up | 100–120 V AC / 198–242 V AC selectable, 47–63 Hz, ≥ 100 VA; 60-minute warm-up | ||
| Dimensions (W × H × D) | 430 × 177 × 265 mm | 430 × 177 × 265 mm | 430 × 177 × 405 mm |
| Weight | 11 kg | 11 kg | 17 kg |
Source: TH2840X Series Datasheet, Rev. 2026-09. Specifications subject to change without notice.
Interfaces
- RS232standard
- LANstandard, 10/100BaseT
- Handlerstandard
- USB Hoststandard (2 ports)
- USB Devicestandard
- External DC biasstandard
- SCPI / MODBUSstandard
- LCR functionoptional (TH2840X-LCR)
Accessories
Standard accessories
| Item | Description |
|---|---|
| — | EU power cable (Schuko, CEE 7/7) |
| TH26011BS | Four-terminal Kelvin test cable |
| TH26004B | Two-terminal test cable |
| TH26016 | 36-pin scan control cable (AX/BX only) |
| TH1801-001 | Foot switch (AX/BX only) |
| TH1901B | Manual transformer scan fixture (AX/BX only) |
| TH2829AX-001 | Foot switch (NX only) |
TH1901B (manual clamp) is the default scan fixture; TH1901A (pneumatic) is for production lines. The fixture head can be custom-machined to a specific transformer footprint; please supply mechanical drawings of the DUT pin layout. More fixtures are available on request from Techmize or your authorized distributor.
Photos of fixtures and accessories: click an item code above, or browse all accessories.
Downloads
Interested in the TH2840X Series?
Send us the model, quantity and your application. Our team in Ismaning will answer by email.