Transformer Test Systems

TH2840X Series

Automatic Transformer Test System, up to 2 MHz

A dual-CPU, embedded-Linux test system developed as a functional extension of the TH2840 platform and optimized for transformer testing. A 10.1" capacitive touchscreen with graphical pin-association mapping puts winding setup, scan conditions and pass/fail limits on a single page — for switching-transformer and network-transformer scanning, balun/isolation-transformer testing, multi-channel DCR scanning and passive-component and impedance-network analysis.

TH2840AXTH2840BXTH2840NX CE

Technical question about this series? Ask our team.

Key features

  • Dual-CPU architecture, embedded Linux; touch, mouse and keyboard operation, built-in help
  • 10.1" 1280 × 800 capacitive touchscreen; up to 288 test pins on TH2840NX
  • Test speed up to 1800 readings/s (0.56 ms Fast+, ≥ 2 kHz); electronic range switching, no relay noise or wear
  • Test level up to 20 Vrms; built-in DC bias ±40 V / ±100 mA, internal current source to 2 A
  • Graphical pin-association mapping page for winding setup
  • Lk (leakage inductance) setup entered directly at each winding pin
  • Balance scan with 10 points
  • Single-page setup for all transformer test conditions and series/parallel pin wiring
  • SCPI and MODBUS standard; RS232, LAN, 2 × USB Host, USB Device, Handler and external DC-bias control standard
  • Optional TH2840X-LCR module adds full four-parameter LCR bridge measurement

3 models, one platform

TH2840AX

Compact bench platform, 20-pin scanning

Frequency
20 Hz – 500 kHz
Test pins
20 (TH1901)
Enclosure
430 × 177 × 265 mm
Weight
11 kg
Request a quote for TH2840AX

TH2840BX

Same enclosure, extended to 2 MHz

Frequency
20 Hz – 2 MHz
Test pins
20 (TH1901)
Enclosure
430 × 177 × 265 mm
Weight
11 kg
Request a quote for TH2840BX

TH2840NX

Deep chassis, internal scan board to 288 pins

Frequency
20 Hz – 500 kHz
Test pins
48 – 288
Enclosure
430 × 177 × 405 mm
Weight
17 kg
Request a quote for TH2840NX

TH2840AX and TH2840BX share an identical 265 mm-deep enclosure and connect to the DUT through the external TH1901 scan fixture (20 pins). TH2840NX uses a deeper 405 mm chassis with an internal 48-pin scan board, expandable in 48-pin steps (up to six boards) to 288 pins. All three models support the optional TH2840X-LCR bridge function and ship with SCPI/MODBUS as standard. The standard TH2840X does not include a standalone LCR-meter function; order the TH2840X-LCR option for complete four-parameter LCR measurement.

Applications

Transformers and inductive components

Switching-transformer and network-transformer scanning with comprehensive characteristic analysis; balun and isolation-transformer testing.

Discrete passives and relays

Multi-channel scanning of discrete L, R and C components; relay drive-coil and contact-resistance multi-channel testing.

Production integration

Multi-channel DCR scanning; impedance-network analysis; Handler-based bin sorting for automated test cells.

Industries and application examples

Technical specifications

ParameterTH2840AXTH2840BXTH2840NX
Display 10.1" capacitive touchscreen, 1280 × 800, 16:9
Test pins 20 (via TH1901 scan box)20 (via TH1901 scan box)48 – 288 (48 × 6 internal boards)
Frequency range 20 Hz – 500 kHz20 Hz – 2 MHz20 Hz – 500 kHz
Frequency accuracy 0.01%
Frequency resolution 0.1 mHz (20 – 99.9999 Hz), 1 mHz (100 – 999.999 Hz), 10 mHz (1 – 9.99999 kHz), 100 mHz (10 – 99.9999 kHz), 1 Hz (100 – 999.999 kHz), 10 Hz (1 – 2 MHz, BX only)
AC test signal mode Rated value (ALC OFF): set voltage = open-circuit Hcur voltage, set current = short-circuit Hcur current. Constant value (ALC ON): holds DUT voltage/current at the set value
Test voltage range 5 mVrms – 20 Vrms5 mVrms – 20 Vrms (≤ 1 MHz) / 5 mVrms – 15 Vrms (> 1 MHz)5 mVrms – 20 Vrms
Test voltage accuracy ±(10% × setting + 2 mV) (AC ≤ 2 Vrms); ±(10% × setting + 5 mV) (AC > 2 Vrms)
Test current range 50 µArms – 100 mArms
RDC test signal Voltage 100 mV – 20 V (1 mV / 10 mV res.); current 0 – 100 mA (10 µA / 100 µA res.)
DC bias Voltage 0 – ±40 V (1 mV / 10 mV res.); current 0 – ±100 mA (10 µA / 100 µA res.)
Built-in current source 0 – 2 A, accuracy ±(2% × setting + 2 mA) at I > 5 mA, 1 mA resolution
Output impedance 30 Ω ±4% @ 1 kHz or 100 Ω ±2% @ 1 kHz, selectable
Transformer test parameters Cs/Cp, Ls/Lp, DCR, Zx, Rs/Rp, D, Q, dZ (phase angle), Lk (leakage inductance), phase, balance, turns ratio (Ns:Np = U2/U1), turns (Ns = Np × U2/U1)
Transformer test mode Continuous: one trigger measures all set parameters. Step: one trigger per parameter
Transformer measurement speed Fast+ 1 ms (> 10 kHz), fast 3.3 ms, medium 90 ms, slow 220 ms
Averaging / delay Each test parameter has independent averaging (0 – 255 readings) and independent delay time
Internal scan board None — external TH1901 scan boxNone — external TH1901 scan box1 board standard, expandable to 6 (24 × 2 pins per board, 288 pins max.)
Handler pin definition NS1–NS9, GOOD, NG, TEST, TRIGGER, RESETNS1–NS9, GOOD, NG, TEST, TRIGGER, RESETNS1–NS30, GOOD, NG, TEST, TRIGGER, RESET
Windings Primary up to 60, secondary up to 9
Test lead interface 25 × 2-pin FRC socket
External scan box Compatible with TH1901 series, TH1831
LCR function (optional TH2840X-LCR) Cp/Cs, Lp/Ls, Rp/Rs, |Z|, |Y|, R, X, G, B, θ, D, Q (AC); RDC, VDC, IDC (DC), any 4 parameters simultaneously; 0.05% basic accuracy; fast+ 0.56 ms, fast 3.3 ms, medium 90 ms, slow 220 ms
Storage Internal approx. 100 MB non-volatile memory, up to 500 setting files; USB for settings, screenshots, log files
External DC bias control TH1778A, up to 6 units / 120 A
Power / warm-up 100–120 V AC / 198–242 V AC selectable, 47–63 Hz, ≥ 100 VA; 60-minute warm-up
Dimensions (W × H × D) 430 × 177 × 265 mm430 × 177 × 265 mm430 × 177 × 405 mm
Weight 11 kg11 kg17 kg

Source: TH2840X Series Datasheet, Rev. 2026-09. Specifications subject to change without notice.

Interfaces

  • RS232standard
  • LANstandard, 10/100BaseT
  • Handlerstandard
  • USB Hoststandard (2 ports)
  • USB Devicestandard
  • External DC biasstandard
  • SCPI / MODBUSstandard
  • LCR functionoptional (TH2840X-LCR)

Accessories

Standard accessories

ItemDescription
—EU power cable (Schuko, CEE 7/7)
TH26011BSFour-terminal Kelvin test cable
TH26004BTwo-terminal test cable
TH2601636-pin scan control cable (AX/BX only)
TH1801-001Foot switch (AX/BX only)
TH1901BManual transformer scan fixture (AX/BX only)
TH2829AX-001Foot switch (NX only)

Optional test fixtures

ItemDescription
TH1901APneumatic transformer scan fixture (requires compressed-air supply)
TH26007AToroidal-core test fixture
TH26008ASMD component test fixture
TH26009BSMD component test tweezers
TH26077Dielectric test fixture

TH1901B (manual clamp) is the default scan fixture; TH1901A (pneumatic) is for production lines. The fixture head can be custom-machined to a specific transformer footprint; please supply mechanical drawings of the DUT pin layout. More fixtures are available on request from Techmize or your authorized distributor.

Photos of fixtures and accessories: click an item code above, or browse all accessories.

Downloads

Interested in the TH2840X Series?

Send us the model, quantity and your application. Our team in Ismaning will answer by email.